Cuvettes
Produkte filtern
–
Standard Rectangular Cells
Capacity: 3.5 ml | Description: with cover | Ext. depth: 12.5 mm | Ext. height: 45 mm | Ext. width: 12.5 mm | External dimensions (W x D x H) mm: 12.5 x 12.5 x 45 | External dimensions (WxDxH): 12.5 x 12.5 x 45 mm | Int. width: 10 mm | Internal width mm: 10 | Manufacturer Article Number: 1/G/10 | Max. capacity: 3.5 ml | Path length: 10 mm | Path length mm: 10 | Type: 1/G/10 | Type: 1/G/10 | Type of closure: Lid | Type of cuvette: Standard | Volume ml: 3.500
High precision standard cells for routine analysis. Suitable for most spectral photometers, using rectangular cells. Available with cover or with stopper for a liquid-tight seal. Cover and stopper made of PTFE.Glass typesType G: Optical glass, 334 to 2500 nmType SOG: Special optical glass, 320 to 2500 nmType Q: Spectrosil® Far UV Quartz glass, 190 to 2700 nm
Produktnummer: 1/G/10-4678102
Hersteller: Starna Scientific Ltd.
Standard rectangular fluorometer cells
Capacity: 3.5 ml | Description: with cover | Ext. depth: 12.5 mm | Ext. height: 45 mm | Ext. width: 12.5 mm | External dimensions (W x D x H) mm: 12.5 x 12.5 x 45 | External dimensions (WxDxH): 12.5 x 12.5 x 45 mm | Int. width: 10 mm | Internal dimensions (W x D x H) mm: 10 | Manufacturer Article Number: 3/Q/10 | Max. capacity: 3.5 ml | Path length: 10 mm | Path length mm: 10 | Type: 3/Q/10 | Type: 3/Q/10 | Type of closure: Lid | Type of cuvette: Standard | Volume ml: 3.500
High precision standard cells for routine analysis. Suitable for most spectral photometers, using rectangular cells. Available with cover or with stopper for a liquid-tight seal. Cover and stopper made of PTFE.Glass typesType G: Optical glass, 334 to 2500 nmType SOG: Special optical glass, 320 to 2500 nmType Q: Spectrosil® Far UV Quartz glass, 190 to 2700 nm
Produktnummer: 3/Q/10-4678114
Hersteller: Starna Scientific Ltd.
LLG-Cuvette rack, PP
Autoclavable: Yes | Depth: 70 mm | Dimensions (WxDxH): 210 x 70 x 35 mm | Height: 35 mm | Height mm: 35 | Length mm: 210 | Manufacturer Article Number: 4682061 | Material: PP | No. of positions: 16 | UNSPSC: 41-12-28-00 | Width: 210 mm | Width mm: 70
Ideal for storing up to 16 cuvettes with 10 mm width. Two-tier arrangement of the cuvette rows ensures clarity.Numbered positionsAutoclavable at 121 °C
Produktnummer: 4682061-4682061
Hersteller: LLG Labware
Cells for Absorption Measurement, Flow-Through Measurement, UV-range
Capacity µl: 750 | Centre height mm: 8.5 | Description: Supply and outlet tubes | External dimensions (W x D x H) mm: 12.5 x 12.5 x 38.5 | Internal width mm: 11 x 6.5 | Manufacturer Article Number: 175-85-10-40 | Material: QS | Path length mm: 10 | Type: macro | UNSPSC: 41-12-18-13
Optical material: QS: Quartz glass High Performance, wavelength range: 200 - 2500 nm.OS: Special Optical Glass, wavelength range: 320 - 2500 nm.* M 6 x 1 and FEP tubes (outside diameter 1.9mm, inner diameter 1.1mm, length 500mm)
Produktnummer: 175-85-10-40-6072360
Hersteller: Hellma GmbH & Co. KG
Cells for Fluorescence Measurement, UV-range
Description: PTFE stopper, for magnetic stirrers | External dimensions (W x D x H) mm: 12.5 x 12.5 x 49.5 | Manufacturer Article Number: 119004F-10-40 | Path length mm: 10 x 4 | Type: semi-micro | UNSPSC: 41-12-18-13 | internal width (mm) / aperture (mm x mm/Ø): 4
Wavelength Range: 200 nm - 2500 nmOptical material: Quartz glass High Performance
Produktnummer: 119004F-10-40-6080511
Hersteller: Hellma GmbH & Co. KG
Sample Cups for Analyzers, PS
For: Technicon®, Beckman®, Konelab® | Height: 22.6 mm | Manufacturer Article Number: 02501004 | Nominal capacity: 1.50 ml | UNSPSC: 41-12-18-03 | Ø: 13.80 mm
PS sample cup for analyzers.
Produktnummer: 02501004-6207279
Hersteller: Kartell S.p.A.
Macro cuvettes, plastic
Capacity: 4.0 ml | Description: Macro | Dimensions (W x D x H) mm: 12.5 x 12.5 x 45 | Ext. depth: 12.5 mm | Ext. height: 45 mm | Ext. width: 12.5 mm | External dimensions (WxDxH): 12.5 x 12.5 x 45 mm | Manufacturer Article Number: 27 22 110 | Material: Plastic | Max. capacity: 4.0 ml | Nominal capacity ml: 4.0 | Operating range nm: 220 ... 900 | Path length: 10 mm | Path length mm: 10 | Type of cuvette: Macro | UNSPSC: 41-12-18-13 | Wavelength: 220...900 nm
For photometric measurements even in the UV range.Applicable wavelength range 220 to 900 nmLow variation of extinction valuesGood optical transmission rangeSorted by mould cavity numberScope of supply: 100 netidentical cuvettes in styrofoam box with a resealable cover
Produktnummer: 27 22 110-6225579
Hersteller: Ratiolab GmbH
Secondary standards for calibrating spectrophotometers
Description: Calibration set according to European Pharmacopoeia, contains filter UV1, UV12 | GHS: GHS02, GHS07, GHS08, GHS09 | Manufacturer Article Number: 667100 | Type: 667.100-UV | UNSPSC: 41-11-61-07
To maintain constant good measurement results, a regular review of the accuracy of the spectrophotometer is required. With the use of certified reference materials from Hellma Analytics, you make sure that your equipment qualifications meet the requirements of the pharmacopoeias and fulfill your internal quality requirements, at the same time you reach the international comparability of your measurement results. The certified reference materials (calibration standards) of the DIN EN ISO 17025 accredited Hellma Analytics calibration laboratory are traceable to the primary standards of NIST (National Institute of Standards and Technology) and meet the requirements of the major pharmacopoeias (e.g. EP, DAB, USP).Your benefits: High quality of the measurement resultsInternational comparability of measurement resultsMeeting the requirements of the major pharmacopoeias (EP, DAB, USP)Results traceable to NIST primary standards30 years warranty on the reference materialsScope of delivery: Certified reference materials (Calibration Standards) in quality storage boxDAkkS Calibration Certificate (DIN 17025)Handling guidelinesCheck for stray lightHazardous Substance DataGHSSignal wordGefahrH-SatzH225, H304, H315, H319, H336, H361fd, H373, H411P-SatzP210, P261, P273, P281, P301+P310, P305+P351+P338SDSLink
Produktnummer: 667100-6228184
Hersteller: Hellma GmbH & Co. KG
Lids for Sample Cups, PE
Dimensions (ØxH): 16 x 8.5 mm | Height: 8.5 mm | Manufacturer Article Number: 0251400 | Material: PE | UNSPSC: 41-12-18-14 | Ø: 16 mm
* optional push-in stopper is available.
Produktnummer: 0251400-6231689
Hersteller: Kartell S.p.A.
Square sample cells, glass
Description: Square sample cells, glass | Manufacturer Article Number: 2495402
For photometric measurements in liquids. Matched pair.Specificationsoptical path length:25,4 mm (1 inch)Volume:10 ml
Produktnummer: 2495402-6241046
Hersteller: HACH LANGE GmbH
Flow-through cells with two optical paths lengths, Absorption and Fluorescence Measurement
Capacity: 550 µl | Capacity µl: 550 | Centre height: 8.5 mm | Centre height mm: 8.5 | Ext. depth: 12.5 mm | Ext. height: 35 mm | Ext. width: 12.5 mm | External dimensions (W x D x H) mm: 35 x 12.5 x 12.5 | External dimensions (WxDxH): 12.5 x 12.5 x 35 mm | Int. width: 6 mm | Manufacturer Article Number: 176-760-85-40 | Material: Quartz glass | Max. capacity: 550 µl | Path length: 5/10 mm | Path length mm: 5 x 10 | Type: semi-micro* | Type of cuvette: Semi-Micro | Wavelength: 200...2500 nm | internal width (mm) / aperture (mm x mm/Ø): 11 x 6/11 x 5
Wavelength Range: 200nm - 2500nmOptical material: Quartz glass High Performance
Produktnummer: 176-760-85-40-6266794
Hersteller: Hellma GmbH & Co. KG
Cuvette rack with attached lid, PP
Depth: 112 mm | Dimensions (WxDxH): 120 x 112 x 60 mm | Height: 60 mm | Manufacturer Article Number: 098.03.001B | Material: PP | No. of positions: 12 | Width: 120 mm
For safe handling and holding up to 12 cuvettes with a 10 mm light path. These racks consist of hinged lids with secure clasps and removable inserts for easy cleaning. The height of the lid is designed to accommodate all spectrophotometer cells - even those with covers or stoppers.
Produktnummer: 098.03.001B-6267353
Hersteller: ISOLAB Laborgeräte GmbH
Plastic Cuvettes with Lid
Manufacturer Article Number: 145510 | Volume ml: 10
Produktnummer: 145510-6288081
Hersteller: Tintometer GmbH
Secondary standard Didymium RM-DG for calibrating spectrophotometers
Manufacturer Article Number: RM-DG | Type: RM-DG | Wavelength nm: 430 ... 890
For checking the wavelength accuracy. NIST traceable and acc. to ISO 17025
Produktnummer: RM-DG-6320155
Hersteller: Starna Scientific Ltd.
Cells for Absorption Measurement, NIR-range
Capacity: 1,400 µl | Capacity µl: 1400 | Description: 2 PTFE-stopper | Ext. depth: 4.5 mm | Ext. height: 47.5 mm | Ext. width: 23.6 mm | External dimensions (W x D x H) mm: 23.6 x 4.5 x 47.5 | External dimensions (WxDxH): 23.6 x 4.5 x 47.5 mm | Int. width: 18.5 mm | Internal width mm: 18.5 | Manufacturer Article Number: 404-2-46 | Material: Quartz glass | Material closure: PTFE | Max. capacity: 1400 µl | Path length: 2 mm | Path length mm: 2 | Type: macro | Type of closure: Stopper | Type of cuvette: Macro | UNSPSC: 41-12-18-13 | Wavelength: 200...3500 nm
300 Wavelength Range: 200nm - 3500nmOptical material: Quartz glass Extended Range
Produktnummer: 404-2-46-6800243
Hersteller: Hellma GmbH & Co. KG
Cells for Absorption Measurement, Vis-range
Capacity µl: 6000 | Description: Large cuvette, glass lid | External dimensions (W x D x H) mm: 25 x 25 x 22.5 | Internal width mm: 20 | Manufacturer Article Number: 704-000-20-10 | Path length mm: 20 ± 0.2 | Type: large cuvette | optical material: OG
Wavelength Range:Optical material:260nm - 2500nmHOQ 310H (UV)320 nm - 2500 nm Special optical glass (OS)360 nm - 2500 nm Optical glass (OG)
Produktnummer: 704-000-20-10-7637932
Hersteller: Hellma GmbH & Co. KG
HELLMANEX® III liquid
Capacity: 1 l | Capacity l: 1 | GHS: GHS05, GHS07 | Manufacturer Article Number: 9-307-011-4-507 | Safety Data Sheet: https://sds.llg.de/?s=1&artnr_manuals=9190985 | Supply form: Liquid concentrate | Type: HELLMANEX® III | Type: HELLMANEX® III | Type of packaging: Bottle
Cleaning:HELLMANEX® III is an alkaline liquid concentrate used for the highly effective cleaning of glass or silica cells and other sensitive optical components. Laboratory equipment made of glass, quartz, sapphire and porcelain can also be cleaned using the solution.Characteristics:Hellmanex® III significantly reduces the surface tension of water. The removal of dirt particles is also assured by the good wetting action of a Hellmanex® III aqueous solution, whilst its high emulsifying and dispersing capabilities prevent the re-deposition of the loosened particles. Special surface-active substances facilitate the residue-free rinsing of the optical components once they have been cleaned.Cleaning and Dilution:The optimal dilution depends on several factors, such as the hardness of the water, the degree and type of contamination, the temperature, etc. The use of demineralised water improves the cleaning characteristics.Available in 1.3kg PE-bottle.The following treatments have been proven at a concentration (vol%) 0.5 to 2 in practice.Hazardous Substance DataGHSSignal wordAchtungH-SatzH290, H315, H319, H335P-SatzP234, P261, P312, P332+P313, P403+P233, P405UNNR3266SDSLink
Produktnummer: 9-307-011-4-507-9190985
Hersteller: Hellma GmbH & Co. KG
LLG-Disposable plastic cells, PS
Capacity: 4.0 ml | Description: Macro | Ext. depth: 12.5 mm | Ext. height: 45 mm | Ext. width: 12.5 mm | External dimensions (WxDxH): 12.5 x 12.5 x 45 mm | Manufacturer Article Number: 9406011 | Material: PS | Material: PS | Max. capacity: 4.0 ml | Operating range nm: 340 to 900 | Path length: 10 mm | Path length mm: 10 | Type of cuvette: Macro | Volume ml: 4.0 | Wavelength: 340...900 nm
The shape and narrow wall thickness of the cuvettes enable an excellent heat transfer resulting in constant sample temperatures during photometric measurements.Cavity sortedGlass clear polystyrene (PS)Applicable wavelength range 340 nm to 900 nmVery low variation of extinction valuesExcellent optical transmission rangePath length 10 mmOverall dimensions 12.5 mm x 12.5 mm x 45 mmStyrofoam racks: 100 cuvettes in a styrofoam box with cover
Produktnummer: 9406011-9406011
Hersteller: LLG Labware
Disposable cuvettes, macro
Capacity: 4.5 ml | Ext. depth: 12 mm | Ext. height: 45 mm | Ext. width: 12 mm | External dimensions (WxDxH): 12 x 12 x 45 mm | Manufacturer Article Number: 0193700 | Material: PS | Max. capacity: 4.5 ml | Path length: 10 mm | Type of cuvette: Macro | Wavelength: 340...800 nm
Cuvettes for spectrophotometry applications in the visible spectrum. The production technology and quality control ensure the reproducibility of the cuvettes. The absorption changes are kept within the ±1 % interval, an important condition for analyses in series.Cuvettes for spectrophotometry applications in the visible spectrum. The production technology and quality control ensure the reproducibility of the cuvettes. The absorption changes are kept within the ±1 % interval, an important condition for analyses in series.
Produktnummer: 0193700-9406431
Hersteller: Kartell S.p.A.
Disposable cuvettes, semi-micro
Capacity: 1.5 ml | Ext. depth: 12 mm | Ext. height: 45 mm | Ext. width: 12 mm | External dimensions (WxDxH): 12 x 12 x 45 mm | Manufacturer Article Number: 0193800 | Material: PS | Max. capacity: 1.5 ml | Path length: 10 mm | Type of cuvette: Semi-Micro | Wavelength: 340...800 nm
Cuvettes for spectrophotometry applications in the visible spectrum. The production technology and quality control ensure the reproducibility of the cuvettes. The absorption changes are kept within the ±1 % interval, an important condition for analyses in series.Cuvettes for spectrophotometry applications in the visible spectrum. The production technology and quality control ensure the reproducibility of the cuvettes. The absorption changes are kept within the ±1 % interval, an important condition for analyses in series.
Produktnummer: 0193800-9406432
Hersteller: Kartell S.p.A.
Disposable cuvettes, standard, 4 clear faces
Capacity: 4.5 ml | Ext. depth: 12 mm | Ext. height: 45 mm | Ext. width: 12 mm | External dimensions (WxDxH): 12 x 12 x 45 mm | Manufacturer Article Number: 0196000 | Material: PS | Max. capacity: 4.5 ml | Path length: 10 mm | Type of cuvette: Standard | Wavelength: 340...800 nm
Cuvettes for spectrophotometry applications in the visible spectrum. The production technology and quality control ensure the reproducibility of the cuvettes. The absorption changes are kept within the ±1 % interval, an important condition for analyses in series.Cuvettes for spectrophotometry applications in the visible spectrum. The production technology and quality control ensure the reproducibility of the cuvettes. The absorption changes are kept within the ±1 % interval, an important condition for analyses in series.
Produktnummer: 0196000-9406434
Hersteller: Kartell S.p.A.
Accessories for standard and semi-micro cuvettes
Description: Disposable stirrer, 90 mm, Ø 3 mm | Manufacturer Article Number: 0093900 | Material: PS
Produktnummer: 0093900-9406439
Hersteller: Kartell S.p.A.


















